Generator and modulator tubes |
| Name | Type | Brief application | Cooling method | Output power | Maximum anode voltage | Maximum operating frequency | | G811 | triode | oscillation | air | 40 W | 5 kV | 110 MHz | | G433 | triode | oscillation | forced water | 60kW | 40kV | | | G807 | beam tetrode | oscillation, amplification | air | 25W | 600V | 60MHz | | GI11B | pulse triode | oscillation | forced air | 80W | 0,8kV/2kV in pulse | 14cm | | GI12B | pulse triode | amplification, oscillation | forced air | 80W | 0,8kV/2kV in pulse | 9cm | | GI130M | pulse triode | oscillation | forced air | 20W/110W in pulse | 0,9kV | 9cm | | GI13BM | pulse triode | Oscillation | forced air | 110W | 1kV/4kV in pulse | 9cm | | GI14B | pulse triode | Oscillation | forced air | 500W/100kW in pulse | 21kV | 30cm | | GI150 | pulse triode | oscillation | forced air | 3W/100W in pulse | 0,8kV/4kV in pulse | 7cm | | GI15B | pulse triode | oscillation | forced air | 3W/100W in pulse | 0,8kW/4kW in pulse | 7cm | | GI16B | pulse tetrod | oscillation, amplification | forced air | 2,5kW/60kW in pulse | 13,2kV | | | GI17 | pulse triode | Oscillation | forced air | 150W/100kW in pulse | 9kV in pulse | 500MHz | | GI18B | pulse triode | oscillation, amplification | forced air | 6kW | 16,5kV | 160kHz | | GI18BM | pulse triode | oscillation, amplification | forced air | 6kW/300kW in pulse | 16,5kV | 160kHz | | GI19B | pulse triode | Oscillation | forced air | 1kW/230kW in pulse | 14kV | metric band | | GI210 | pulse triode | oscillation | forced air | 25W/4kW in pulse | 0.8kV/5kV in pulse | 10cm | | GI21B | pulse triode | oscillation, amplification | forced air | 110W | 0,8kV/5kV in pulse | 9,5cm | | GI22 | pulse triode | oscillation | forced air | 375W | 2kV | 5000MHz | | GI23 | pulse triode | oscillation, amplification | forced air | 300W/40kW in pulse | 1,3kV/14kV in pulse | 28cm | | GI24A | pulse triode | amplification | forced water | 25kW/1000kW in pulse | 27kV | 170MHz | | GI25 | pulse triode | oscillation | forced air | 1200W | 3kV in pulse | 5400MHz | | GI26A | pulse triode | amplification | forced water | 60kW/11MW in pulse | 30kV | 25MHz | | GI26B | pulse triode | amplification | forced air | 20kW/3MW in pulse | 30kV | 25MHz | | GI27A | pulse triode | oscillation, amplification | forced water | 25kW/4MW in pulse | 40kV | 150MHz | | GI27A-1 | pulse triode | oscillation, amplification | forced water | 25kW/5MW in pulse | 40kV | 150MHz | | GI2A | pulse beam tetrode | amplification | forced water | | 66kV | | | GI3 | pulse triode | oscillation | air | 10W | 2,8kV | 300MHz | | GI30 | double pulse beam tetrode | | air | | 5kV | | | GI31 | pulse triode | oscillation | air | 12W/1,5kW in pulse | 2,8kV | 2100MHz | | GI31R | pulse triode | oscillation | forced air | 12W/1,2kW in pulse | 2,8kV | 7cm | | GI33 | pulse beam tetrode | amplification, multiplication | forced air | 0,7kW/4kW in pulse | 5kV | 650MHz | | GI34A | pulse tetrod | amplification | forced water | 100kW | 12kV | 100kHz | | GI35B | pulse triode | amplification | forced air | 5kW/225kW in pulse | 14kV | 200MHz | | GI36 | pulse beam tetrode | oscillation | air | 25W/3kW in pulse | 2,2kV | | | GI37A | pulse tetrod | oscillation, amplification | forced water | 4kW/100kW in pulse | 15kV | 500MHz | | GI38B | pulse triode | amplification | forced air | 3kW/45kW in pulse | 10kV | 200MHz | | GI39 | pulse triode | oscillation, amplification | forced air | 440W/128kW in pulse | 20kV | 25cm | | GI40A | pulse triode | oscillation, amplification | forced water | 10MW | 30kV | 50MHz | | GI41 | pulse triode | oscillation, amplification | air | 40W/1.5kW in pulse | 3kV | 3000MHz | | GI41-1 | pulse triode | oscillation, amplification | air | 40W/2kW in pulse | 2,4kV/3,2 in pulse | 18cm | | GI42B | pulse triode | amplification | forced air | 18kW/3,5MW in pulse | 35kV | 200MHz | | GI43A | pulse tetrod | oscillation, amplification | forced water | 15kW/500kW in pulse | 25kV | 500MHz | | GI45 | triode | oscillation | air | 3W/10W in pulse | 0,3kV | 3,2cm | | GI46 | pulse triode | oscillation, amplification | forced air | 350W/15kW in pulse | 1,9kV | 28cm | | GI47A | pulse tetrod | amplification | forced water | 30kW/70kW in pulse | 12kV | 100kHz | | GI48 | triode | oscillation, amplification | forced air | 15W/1kW in pulse | 2kV | 900MHz | | GI49B | pulse triode | oscillation, amplification | forced air | 75W/ | 2,4kV/4kV in pulse | 10cm | | GI50A | pulse triode | amplification | forced water | 40kW/2MW in pulse | 32kV | 170MHz | | GI51A | pulse tetrod | amplification | forced water | 30kW/300kW in pulse | 35kV | 500MHz | | GI52A | pulse triode | amplification | forced water | 400kW/5MW in pulse | 41kV | 500MHz | | GI53 | pulse triode | oscillation | forced air | 6W/800W in pulse | 1,6kV | 15cm | | GI56A | pulse triode | oscillation, amplification | forced water | 100kW/25MW in pulse | 40kV | 30MHz | | GI57A | pulse triode | amplification | forced water | 16kW/300kW in pulse | 28kV | 50MHz | | GI58A | pulse tetrod | amplification | forced water | 1,6kW/12kW in pulse | 11kV | 150MHz | | GI5B | pulse triode | oscillation | forced air | 6kW/1200kW in pulse | 27kV | 200MHz | | GI63B | pulse triode | amplification | forced air | 250W/2,3kW in pulse | 3kV | 250MHz | | GI6B | pulse triode | oscillation | forced air | 350W | 2,5kV/5kV in peak | 18cm | | GI70B | pulse triode | Oscillation | forced air | 350W/11kW in pulse | 2,5kV/9kV in pulse | 18cm | | GI70BT | pulse triode | Oscillation | forced air | 350W/11kW in pulse | 2,5kV/9kV in pulse | 18cm | | GI7B | pulse triode | Oscillation | forced air | 350W/11kW in pulse | 2,5kV/9kV in pulse | 18cm | | GI7BT | pulse triode | Oscillation | forced air | 350W/11kW in pulse | 2,5kV/9kV in pulse | 18cm | | GK1A | triode | amplification, oscillation | forced water | 200kW | 10kV | 25MHz | | GK10A | triode | amplification | forced water | 175kW | | | | GK10B | triode | amplification | forced air | 70kW | 10kV | 2MHz | | GK11A | tetrode | amplification | forced water | 120kW/250kW in pulse | 15kV | 30MHz | | GK11P | tetrode | amplification | evaporation | 120 kW | 5 kV | 110 MHz | | GK12A | triode | amplification, oscillation | forced water | 250 kW | 8 kV | 26 MHz | | GK13A | triode | amplification, oscillation | forced water | 30kW/100kW | 11kV | 30MHz | | GK3A | triode | amplification, oscillation | forced water | 2,6kW/100kWt in pulse | 12kV | 25MHz | | GK5A | triode | amplification, oscillation | forced water | 200 kW | 8 kV | 25MHz | | GK71 | pentode | amplification, oscillation | air | 125 W | 2 kV | 20 MHz | | GK750 | triode | oscillation | air | 250W | 3kV | 40MHz | | GK9A | triode | amplification | forced water | 18kW/30kW in pulse | 12kV | 2MHz | | GK9B | triode | amplification | forced air | 180 kW | 0.4 kV | 250 MHz | | GK9P | triode | amplification | evaporation | 250 kW | 0.75 kV | 500 MHz | | GM100 | triode | amplification | air | 1kW | 5kV | | | GM1A | triode | amplification | forced water | 30kW | 6kV | | | GM1P | triode | amplification | forced evaporation | 35kW | 6kV | | | GM3A | triode | amplification | forced water | 7,5kW | 6kV | | | GM3B | triode | amplification | forced water | 7,5kW | 6kV | | | GM3P | triode | amplification | forced evaporation | 7,5kW | 6kV | | | GM51A | triode | amplification | forced water | 15kW | 12,5kV | | | GM60 | triode | amplification | air | 0.6kW | 10kV | | | GM70 | triode | amplification | air | 125W | 1,65kV | | | GMI10 | tetrode | modulation | air | 41W | 9kV | | | GMI10-1 | tetrode | modulation | air | 41W | 9kV | | | GMI11 | tetrode | modulation | air | 85W | 10kV | | | GMI11-1 | tetrode | modulation | air | 85W | 10kV | | | GMI14B | tetrode | modulation | air | 600W | 36kV | | | GMI15B | pulse beam tetrode | modulation | air | 700W | 3,5kV | | | GMI17B | pulse beam tetrode | commutation | forced air | 1,5kW | 30kV | | | GMI19B | pulse tetrode | modulation | forced air | 1kW/3MW in pulse | 30kV | | | GMI20 | pulse tetrode | modulation | air | 15W/20kW in pulse | 3kV | | | GMI21 | pulse tetrode | modulation | air | 30W | 10kV | | | GMI21-1 | pulse tetrode | modulation | air | 30W | 10kV | | | GMI22B | pulse tetrode | modulation | forced air | 250W | 20kV | | | GMI26B | pulse tetrode | modulation | forced air | 250W | 10kV | | | GMI27A | pulse tetrode | modulation | forced water | 1kW/2.75kW in pulse | 6kV | | | GMI27B | pulse tetrode | modulation | forced air | 0,5kW | 10kV | | | GMI28A | pulse triode | commutation | forced water | 6kW/4MW in pulse | 35kV | | | GMI29A-1 | pulse tetrode | commutation | forced water | 20kW/4MW in pulse | 40kV | | | GMI29B | pulse tetrode | commutation | forced air | 10kW | 30kV | | | GMI29B-1 | pulse tetrode | commutation | forced air | 10kW | 35kV | | | GMI2B | pulse tetrode | modulation | air | 0,9kW | 32kV | | | GMI30 | pulse triode | modulation | air | 300W | 30kV | | | GMI32B | pulse tetrode | commutation | forced air | 2kW | 40kV | | | GMI32B-1 | pulse tetrode | commutation | forced air | 2kW | 40kV | | | GMI33A | pulse injectron | commutation | forced water | 5kW/3,5MW in pulse | 70kV | | | GMI34A | pulse triode | commutation | forced water | 3kW/45kW in pulse | 40kV | | | GMI34B | pulse triode | commutation | forced air | 3kW/45kW in pulse | 40kV | | | GMI36B | pulse triode | modulation | forced air | 2kW/1,7MW in pulse | 40kV | | | GMI37A | pulse triode | modulation | forced water | 50kW | 50kV | | | GMI38 | pulse triode | modulation | forced air | 60W | 20kV | | | GMI40B | pulse triode | modulation | forced air | 1kW | 10kV | | | GMI41A | pulse injectron | commutation | forced water | 10kW/35MW in pulse | 180kV | | | GMI42B | pulse triode | modulation | forced air | 0,5kW | 30kV | | | GMI44A | pulse triode | commutation | forced water | 150kW | 60kV | | | GMI45A | combined tetrode | modulation,forming | forced water | 1,5kW | 30kV | | | GMI46B | pulse triode | modulation | forced air | 1kW | 30kV | | | GMI5 | pulse tetrode | modulation | air | 50W | 20kV | | | GMI50B | pulse beam tetrode | modulation | forced air | 250W | 20kV | | | GMI52B | triode | commutation | forced air | 80W/80kW in pulse | 15kV | | | GMI6 | double beam tetrode | modulation | air | 15W | 4kV | | | GMI6-1 | double beam tetrode | modulation | air | 15W | 4kV | | | GMI7 | pulse beam tetrode | modulation | air | 125W | 22kV | | | GMI71 | pulse tetrode | modulation | air | 125W | 22kV | | | GMI83 | pulse tetrode | | forced air | 65W | 20kV | | | GMI83V | pulse tetrode | amplification | forced air | 60W | 18kV | | | GMI89 | pulse tetrode | modulation | air | 100W | 26kV | | | GMI90 | pulse tetrode | | air | 140W | 33kV | | | GS11 | triode | HF amplification, oscillation | forced air | 1.5 W | 9 kV | 10cm | | GS12A | tetrode | amplification | forced water | 26kW | 7kV | 1000MHz | | GS13 | triode | oscillation, amplification, freq.multiplication | forced air | 13W | 0,3kV | 7,2cm | | GS14 | triode | HF amplification, oscillation, freq.multiplication | forced air | 28 W | 10 kV | 7,7cm | | GS14-2 | triode | amplification, oscillation | forced air | 60W/12kW in pulse | 2,5kV | 3280MHz | | GS15B | tetrode | HF amplification, oscillation | forced air | 200 W | 11 kV | 26 MHz | | GS17B | tetrode | HF amplification, oscillation | forced air | 10 kW | 5,5kV | 1000MHz | | GS18B | tetrode | amplification | forced air | 15kW | 6,5kV | 1000MHz | | GS19 | triode | HF amplification, oscillation | air | 1,2W | 175V | 2000MHz | |
| GS1B | triode | | forced air | 360W | 3kV/6kV in peak | 30cm | | GS20 | triode | HF amplification, oscillation | air | 10W | 400V | 7,5cm | | GS21 | triode | HF amplification, oscillation | air | 13W | 400V | 10cm | | GS22 | triode | amplification, oscillation | air | 21W | 375V | 9000MHz | | GS23B | tetrode | HF amplification, oscillation | forced air | 1.5 kW | 0.75 kV | metric waves | | GS24B | triode | amplification, oscillation | forced air | 32W/120W in pulse | 900V | 30cm | | GS25 | triode | HF amplification, oscillation, freq.multiplication | air | 0,21W | 100V | 5000MHz | | GS27B | tetrode | HF amplification | forced air | 100 W | 0.5 kV | 250 MHz | | GS29B | triode | amplification, oscillation | forced air | 50W | 475V | 6000MHz | | GS30 | triode | HF oscillation | air | 40 W | 1.5 kV | 1500 MHz | | GS31B | triode | HF amplification, oscillation | forced air (other) | 1 kW | 1.5 kV | 1030 MHz | | GS32 | triode | HF amplification, oscillation, freq.multiplication | air | 5W | 0,25kV | 2000MHz | | GS33B | tetrode | amplification | forced air | 80W | 1,1kV | 7,5cm | | GS34 | triode | amplification, oscillation | forced air | 60W/12kW in pulse | 2,5kV | 3280MHz | | GS34-1 | triode | amplification, oscillation | forced air | 60W/12kW in pulse | 2,5kV | 3280MHz | | GS35B | triode | HF amplification, oscillation | forced air | 1.5 kW | 4 kV | 250 MHz | | GS36B | tetrode | HF amplification | forced air | 0.4 kW | 2.5 kV | 250 MHz | | GS37 | tetrode | freq.multiplication | | 2.5 W | 8 kV | 250 MHz | | GS38B | tetrode | amplification | forced air | 350W | 3,5kV | 500MHz | | GS39B | tetrode | amplification | forced air | 0,6kW | 2,5kV/4,5kV in peak | 750MHz | | GS3A | beam tetrode | HF amplification | forced water | 3 kW | 2,7kV | 800MHz | | GS3B | beam tetrode | HF amplification | forced air | 2 kW | 2,1kV | 800MHz | | GS41B | tetrode | amplification | forced air | 160W | 1kV | 800MHz | | GS41B-1 | tetrode | amplification | forced air | | | | | GS4V | triode | oscillation, amplification, freq.multiplication | forced air | 15W | 350V | 7500MHz | | GS6V | triode | oscillation, amplification, freq.multiplication | forced air | 28W | 0,45kV | 7,5cm | | GS7A | triode | amplification, oscillation | forced water | 2kW | 6kV | 1000MHz | | GS7B | triode | amplification, oscillation | forced air | 1,5kW | 6kV | 1000MHz | | GS9B | triode | HF oscillation | forced air | 300 W | 10 kV | 100 MHz | | GU100A | triode | amplification, oscillation | forced water | 6 kW | 3.3 kV | 100 MHz | | GU100B | triode | amplification, oscillation | forced air | 6 kW | 3.3 kV | 100 MHz | | GU10A | triode | Amplification, oscillation | forced water | 10 kW | 8kV | 25MHz | | GU10B | triode | Amplification, oscillation | forced air | 10 kW | 8kV | 32 MHz and more | | GU12A | triode | amplification, oscillation | forced water | 20kW | 10,5kV | 50MHz | | GU13 | beam tetrode | Amplification, oscillation | air | 0.1 kW | 2kV | 30MHz | | GU15 | beam pentode | Amplification, oscillation | air | 15W | 700V | 60MHz | | GU17 | double beam tetrode | Amplification, oscillation | air | 12 W | 400V | 250MHz | | GU18 | double beam tetrode | amplification | air | 27W | 0,6kV | 600MHz | | GU18-1 | double beam tetrode | oscillation | air | 13,5W x2 | 0,6kV | 600MHz | | GU19-1 | double tetrode | oscillation, amplification, modulator | air | 40 W | 6 kV | 70 MHz | | GU21B | triode | oscillation, amplification | forced air | 10 kW | 6 kV | 26MHz | | GU22A | triode | oscillation, amplification | forced water | 20 kW | 10kV | 26MHz | | GU23A | triode | oscillation, amplification | forced water | 60 kW | 11kV | 26MHz | | GU23B | triode | oscillation, amplification | forced air | 50 kW | 12 kV | 26MHz | | GU25B | triode | oscillation, amplification | forced air | 15kW | 12kV | 26MHz | | GU27A | tetrode | amplificatio, modulation, oscillation | forced water | 2kW | 4kV | 110MHz | | GU27B-1 | tetrode | amplificatio, modulation, oscillation | forced air | 800W | 3,5kV | 110MHz | | GU29 | double beam tetrode | oscillation, amplification | forced air | 40 W | 0,75kV | 110MHz | | GU30A | triode | oscillation, amplification | forced water | 60kW | 7,5kV | 100MHz | | GU32 | double beam tetrode | oscillation, amplification | air | 15 W | 3.5 kV | 200MHz | | GU32V | double beam tetrode | oscillation, amplification | air | 15 W | 10 kV | 200MHz | | GU33A | tetrode | oscillation, amplification | water | 0.15 kW | 1,5kV | 500MHz | | GU33B | tetrode | amplification | forced air | 0.15 kW | 1,5kV | 500MHz | | GU33P | tetrode | oscillation, amplification | evaporation | 0.15 kW | 1,5kV | 500MHz | | GU34B | tetrode | amplification | forced air | 0.5 kW | 0.7 kV | 250 MHz | | GU34B-1 | tetrode | amplification | forced air | 0.65 kW | 10 kV | 30 MHz | | GU35B-1 | tetrode | oscillation, amplification | forced air | 3,5kW | 5kV | 250MHz | | GU35B | tetrode | oscillation, amplification | forced air | 3,5kW | 5kV | 250MHz | | GU36B | tetrode | amplification | forced air | 14kW | 8kV | 250MHz | | GU36B-1 | tetrode | amplification | forced air | 15 kW | 8kV | 250MHz | | GU39A | tetrode | amplification | forced water | 8kW | 10kV | 100MHz | | GU39A-1 | tetrode | amplification | forced water | 8 kW | 10 kV | 100MHz | | GU39B | tetrode | amplification | forced air | 6kW | 10kV | 100MHz | | GU39B-1 | tetrode | amplification | forced air | 8 kW | 12 kV | 30 MHz | | GU39P-1 | tetrode | amplification | forced evaporation | 10 kW | 12 kV | 30 MHz | | GU4A | triode | oscillation, amplification | forced water | 20kW | 6kV | 100MHz | | GU40B-1 | tetrode | amplification | forced air | 2kW | 5kV | 250MHz | | GU40B | tetrode | amplification | forced air | 2kW | 5kV | 250MHz | | GU42 | double tetrode | oscillation, amplification | air | 40W | 0,75kV | 60MHz | | GU43A | tetrode | oscillation, amplification | water | 1 kW | 3,3kV | 100MHz | | GU43B | tetrode | oscillation, amplification | forced air | 1 kW | 3.5 kV | 75 MHz | | GU44A | tetrode | amplification | forced water | 50 kW | 12kV | 32MHz | | GU44B | tetrode | amplification | forced air | 30kW | 3 kV | 250 MHz | | GU45A | triode | oscillation, amplification, modulator | forced water | 20 kW | 10,5kV | 50MHz | | GU46 | pentode | oscillation, amplification | air | 0.5 kW | 3kV | 60MHz | | GU47A | tetrode | amplification | forced water | 6 kW | 6kV | 70MHz | | GU47B | tetrode | amplification | forced air | 4 kW | 6,5kV | 70MHz | | GU48 | triode | RF heating | air or forced air | 0.3 kW | 1.5 to 3 kV | 75MHz | | GU49A | triode | oscillation, amplification | forced water | 500kW | 11kV | 50MHz | | GU50 | pentode | | air | 40 W | 1kV | 66MHz | | GU53A | tetrode | amplification | forced water | 50 kW | 12 kV | 75MHz | | GU53B | tetrode | amplification | forced air | 45 kW | 12 kV | 60MHz | | GU54A | triode | oscillation, amplification | forced air | 20kW | 10kV | 25MHz | | GU55A | triode | oscillation, amplification | forced water | 60kW | 12kV | 26MHz | | GU56 | triode | oscillation, amplification, RF heating | air | 0.7 kW | 3,5kV | 45MHz | | GU59B | triode | oscillation, amplification | forced air | 6kW | 7kV | 155MHz | | GU59A | triode | oscillation, amplification | forced water | 6kW | 7kV | 155MHz | | GU58A | triode | oscillation, amplification | forced water | 4,5kW | 4,5kV | 300MHz | | GU57A | triode | amplification | forced water | 65kW | 8kV | 250MHz | | GU5A | triode | Amplification, RF heating | forced water | 3.5 kW | 5kV | 110MHz | | GU5B | triode | Amplification, RF heating | forced air | 2.5 kW | 3.8 kV | 250 MHz | | GU61A | tetrode | amplification | forced water | 30kW | 10kV | 70MHz | | GU61B | tetrode | amplification | forced air | 25 kW | 10kV | 60MHz | | GU61P | tetrode | amplification | forced evaporation | 30 kW | 15 kV | 30 MHz | | GU62A | triode | oscillation, amplification | forced water | 40 kW | 10,5kV | 85MHz | | GU62P | triode | oscillation, amplification | forced evaporation | 40 kW | 10,5kV | 85MHz | | GU63 | tetrode | oscillation, amplification | air | 13 W | 7 kV | 250 MHz | | GU64 | tetrode | oscillation | air | 230W | 2kV | 175MHz | | GU65A | triode | oscillation, amplification | forced water | 350kW | 12kV | 30MHz | | GU66A | triode | amplification | forced water | 60 kW | 10kV | 30MHz | | GU66B | triode | amplification | forced air | 60 kW | 10kV | 30MHz | | GU66P | triode | amplification | forced evaporation | 60 kW | 10kV | 30MHz | | GU67A | triode | oscillation, amplification | forced water | 25kW | 11kV | 75MHz | | GU68A | triode | amplification | forced water | 130 kW | 12kV | 30MHz | | GU68P | triode | amplification | forced evaporation | 130 kW | 12kV | 30MHz | | GU70B | tetrode | amplification | forced air | 0.35 kW | 2kV | 500MHz | | GU71B | pentode | amplification | forced air | 1.5 kW | 6,5kV | 75MHz | | GU72 | tetrode | amplification | air | 85 W | 450 V | decimetric and centimetric waves | | GU73B | tetrode | amplification | forced air | 2,5kW | 5,5kV | 250MHz | | GU73P | tetrode | amplification | forced evaporation | 2.5 to 3.5 kW | 5.5 kV | 250MHz | | GU74B | tetrode | amplification | forced air | 0.6 kW | 2kV/4kV in peak | 150MHz | | GU75A | tetrode | amplification | forced water | 10kW | 8kV | 75MHz | | GU75P | tetrode | amplification | forced evaporation | 10kW | 8kV | 75MHz | | GU75B | tetrode | amplification | forced air | 6kW | 8kV | 75MHz | | GU76A | tetrode | amplification | forced water | 30 kW | 11kV | 75MHz | | GU76P | tetrode | amplification | forced evaporation | 30 kW | 11kV | 75MHz | | GU76B | tetrode | amplification | forced air | 30 kW | 11kV | 75MHz | | GU78B | tetrode | amplification | forced air | 2.5 kW | 300V/6,2kV in peak | 250MHz | | GU77B | tetrode | amplification | forced air | 2kW | 2,2kV/4,25kV in peak | 250MHz | | GU8 | triode | oscillation | air | 100W | 3kV | 40MHz | | GU80 | pentode | amplification | air | 0,6kW | 3kV | 50MHz | | GU81M | pentode | amplification, oscillation | air | 0.45 kW | 550 V | 50MHz | | GU82B | tetrode | amplification | forced air | 1kW | 2kV/4kV in peak | 250MHz | | GU83B | tetrode | amplification | forced air | 25kW | 12kV | 75MHz | | GU84B | tetrode | amplification | forced air | 2,5kW | 2,2kV/4,25kV in peak | 300MHz | | GU83K | tetrode | amplification | forced air | 1,6kW | 2kV/3,75 in peak | 250MHz | | GU88A | triode | amplification, oscillation | forced water | 400 kW | 3 kV | 1000 MHz | | GU88P | triode | amplification, oscillation | forced evaporation | 250 kW | 2.1 kV | 500 MHz | | GU89A | triode | amplification, oscillation and modulation | forced water | 5kW | 8,5kV | 25MHz | | GU89B | triode | amplification, oscillation and modulation | forced air | 5kW | 8,5kV | 25MHz | | GU90B | tetrode | amplification | forced air | 6kW | 8kV | 75MHz | | GU91B | tetrode | amplification | forced air | 0.7 kW | 2kV/3,75 in peak | 250MHz | | GU92B | tetrode | amplification | forced air | 25 kW | | | | GU93B | tetrode | amplification | forced air | 4 kW | 1.25 kV | 60 MHz | | GU94A | tetrode | amplification | forced water | 160 kW | 10 kV | 26 MHz | | GU94P | tetrode | amplification | forced evaporation | 100 kW | 12 kV | 2 MHz | | GU96A | triode | amplification, oscillation | forced water | 4 kW | 12 kV | 2 MHz |
|
|
|
 |
|